“Evaluación del sistema de protecciones en las líneas comprendidas entre la Subestación San Rafael, La Cocha, El Calvario, Illuchi 1 E Illuchi 2 de la Empresa Eléctrica Cotopaxi”
dc.contributor.advisor | Proaño Maldonado, Xavier Alfonso | |
dc.contributor.author | Altamirano Solís, Anahí Michelle | |
dc.contributor.author | Chiliquinga Ulloa, Micaela Alexandra | |
dc.date.accessioned | 2024-10-04T14:15:59Z | |
dc.date.available | 2024-10-04T14:15:59Z | |
dc.date.issued | 2024-08 | |
dc.description | La investigación evaluó la coordinación de protecciones en el sistema de subtransmisión de la Empresa Eléctrica Cotopaxi, enfocándose en las líneas entre las subestaciones San Rafael, La Cocha, El Calvario, Illuchi 1 e Illuchi 2. Inicialmente, se delimitó el área de estudio y se analizaron las protecciones existentes. Un análisis de cortocircuito mostró que las protecciones ANSI 50 y ANSI 51, calibradas para el sistema radial, no eran adecuadas para la nueva topología mallada debido a la bidireccionalidad del flujo de corriente, lo que provocaba la desconexión de elementos no afectados por las fallas. Además, se observó que las protecciones solo estaban presentes en un extremo de las líneas, lo que impedía un despeje oportuno. Para solucionar esto, se propuso un nuevo esquema de coordinación, implementando relés direccionales ANSI 67/67N en ambos extremos de las líneas y transformadores, y protecciones de distancia ANSI 21/21N en las líneas críticas Illuchi 1 – El Calvario e Illuchi 2 – El Calvario. Se ajustaron parámetros como el Ipickup y el tiempo de actuación para asegurar una operación selectiva. La nueva coordinación respetó un margen mínimo de discriminación de 0.2 segundos entre las curvas de protección, mejorando la selectividad y sensibilidad del sistema. | |
dc.description.abstract | The research evaluated the protection coordination in the Cotopaxi Electric Company's sub-transmission system, focusing on the lines between the substations San Rafael, La Cocha, El Calvario, Illuchi 1, and Illuchi 2. First, the study area was delimited, and the existing protections were analyzed. A short-circuit analysis revealed that the ANSI 50 and ANSI 51 protections, designed for a radial system, were inadequate for the new meshed topology due to the bidirectional nature of the current flow, leading to the disconnection of elements not affected by faults. Additionally, it was observed that protections were only present at one end of the lines, hindering timely fault clearance. To overcome this, a new coordination scheme was presented involving the implementation of directional relays ANSI 67/67N at both ends of the lines and transformers, along with distance protections ANSI 21/21N on the critical Illuchi 1 – El Calvario and Illuchi 2 – El Calvario lines. Parameters such as iPickup and operating time were adjusted to ensure selective operation. The new coordination maintained a minimum discrimination margin of 0.2 seconds between the protection curves, significantly enhancing the system’s selectivity and sensitivity. | |
dc.format.extent | 130 páginas | |
dc.identifier.citation | Altamirano Anahí, Chiliquinga Micaela y Chiliquinga Ulloa Micaela Alexandra (2024); “Evaluación del sistema de protecciones en las líneas comprendidas entre la Subestación San Rafael, La Cocha, El Calvario, Illuchi 1 E Illuchi 2 de la Empresa Eléctrica Cotopaxi”UTC, Latacunga.130 paginas. | |
dc.identifier.other | PI-002918 | |
dc.identifier.uri | https://repositorio.utc.edu.ec/handle/123456789/12252 | |
dc.language.iso | es | |
dc.publisher | Ecuador: Latacunga: Universidad Técnica de Cotopaxi: (UTC) | |
dc.subject | SISTEMA DE PROTECCIONES | |
dc.subject | RELÉ DE SOBRECORRIENTE DIRECCIONAL | |
dc.subject | FALLAS ELÉCTRICAS | |
dc.subject | SISTEMAS MALLADOS | |
dc.title | “Evaluación del sistema de protecciones en las líneas comprendidas entre la Subestación San Rafael, La Cocha, El Calvario, Illuchi 1 E Illuchi 2 de la Empresa Eléctrica Cotopaxi” | |
dc.type | Thesis |