“Análisis de la eficiencia energética de las instalaciones del Edificio Académico del Bloque A de la UTC, Extensión La Maná.”
No Thumbnail Available
Date
2025-09
Journal Title
Journal ISSN
Volume Title
Publisher
Ecuador: La Maná: Universidad Técnica de Cotopaxi; Extensión La Maná, Carrera de Electromecánica
Abstract
En edificaciones institucionales, suele presentarse una alta demanda de energía eléctrica asociado a sus múltiples funciones, requiere de un monitoreo continuo que permita identificar áreas de optimización. El estudio se realizó con el objetivo de analizar la eficiencia energética del Edificio Académico del Bloque A de la Universidad Técnica de Cotopaxi, Extensión La Maná. Se aplicó una metodología cuantitativa, descriptiva y aplicada. El proceso de levantamiento de información se realizó mediante el analizador de redes marca Fluke 435 instalado en el tablero del edificio, con mediciones continuas durante 31 días, registrando datos a intervalos, en complemento para la descarga se utilizó la interfaz PowerLog Fluke. Se monitorearon parámetros como voltaje y corriente por fase, potencia activa, reactiva y aparente, energía activa acumulada, factor de potencia, así como los desequilibrios de corriente y potencia trifásica. Se concluyó que el sistema eléctrico presentó tensiones estables cercanas a 132 V por fase y un consumo acumulado de 3.18 MWh durante el período de evaluación, se identificaron desequilibrios de corriente de hasta 30 A entre fases y un factor de potencia que descendió en ciertos momentos a 0.70, en esencia, surge la necesidad de aplicar mejoras técnicas para optimizar la eficiencia y prolongar la vida útil de los equipos.
Description
In institutional buildings, there is usually a high demand for electrical energy associated with its multiple functions, requiring continuous monitoring to identify areas for optimization. The study was carried out with the objective of analyzing the energy efficiency of the Academic Building of Block A of the Technical University of Cotopaxi, La Maná Extension. A quantitative, descriptive and applied methodology was applied. The information gathering process was carried out using the Fluke 435 network analyzer installed on the building's dashboard, with continuous measurements for 31 days, recording data at intervals, as a complement to the download the Fluke PowerLog interface was used. Parameters such as voltage and current per phase, active, reactive and apparent power, accumulated active energy, power factor, as well as current and three-phase power imbalances were monitored. It was concluded that the electrical system presented stable voltages close to 132 V per phase and an accumulated consumption of 3.18 MWh during the evaluation period, current imbalances of up to 30 A between phases and a power factor that decreased at certain times to 0.70 were identified, in essence, the need to apply technical improvements arises to optimize efficiency and extend the useful life of the equipment.
Keywords
EFICIENCIA ENERGÉTICA, CONSUMO, EVALUACIÓN
Citation
Masapanta-Masapanta, E. A., Pazuña-Naranjo, W. P., & Corrales-Bonilla, J. I. (2025). Análisis de la eficiencia energética de las instalaciones del Edificio Académico del Bloque A de la UTC, Extensión La Maná. Journal of Economic and Social Science Research, 5(3), 63-77. https://doi.org/10.55813/gaea/jessr/v5/n3/206