Aplicación del protocolo hart en el proceso de calibración de transmisores de temperatura
| dc.contributor.advisor | Freire Martínez, Luigi Orlando | |
| dc.contributor.author | Siza Tigse, Kevin Alexander | |
| dc.contributor.author | Tigasi Licto, Jairo Israel | |
| dc.date.accessioned | 2026-10-21T14:21:49Z | |
| dc.date.available | 2026-10-21T14:21:49Z | |
| dc.date.issued | 2026-10-14 | |
| dc.description | La investigación tuvo como objetivo aplicar un procedimiento técnico mediante protocolo HART en la calibración de un transmisor de temperatura, con el propósito de identificar la etapa que requería intervención, aplicar el ajuste disponible y evaluar cuantitativamente el error de la variable primaria. El problema se centra en que una verificación basada únicamente en la señal de 4–20 mA no permitiría conocer con claridad el origen del error de medición, por lo que se utilizó la comunicación HART para acceder a la información interna del transmisor y complementar la evaluación. El trabajo se desarrolló mediante un método experimental en un rango de 0 a 100 °C, utilizando un potenciómetro de precisión como simulador resistivo de una Pt100, con valores equivalentes obtenidos mediante la relación resistencia–temperatura establecida en la IEC 60751. Se evaluaron cinco puntos correspondientes al 0 %, 25 %, 50 %, 75 % y 100 % del rango de 0 a 100 °C, registrando la temperatura de referencia, la variable primaria PV y la salida analógica con un comunicador HART 475 OEM; el error de PV se calculó como la diferencia entre el valor medido y la referencia, conforme al JCGM 200:2012. Antes del ajuste Zero PV, los errores fueron +0.14 °C, +0.14 °C, +0.26 °C, +0.29 °C y +0.21 °C. Después del ajuste, disminuyeron a +0.02 °C, +0.01 °C, +0.02 °C, +0.01 °C y +0.02 °C, respectivamente, y se mantuvieron dentro del límite de ±0.1 % del fondo de escala indicado para el transmisor. Como aporte se inicia un procedimiento de verificación, diagnóstico, ajuste y comprobación posterior mediante HART, que podía emplearse como guía en prácticas de instrumentación. Se concluyó que el protocolo HART permitió realizar una intervención técnica sustentada en la comparación de la PV con su referencia y comprobar cuantitativamente la reducción del error después del ajuste. | |
| dc.description.abstract | The objective of this research was to apply a technical procedure using the HART protocol for the calibration of a temperature transmitter in order to identify the stage requiring intervention, apply the available adjustment, and quantitatively evaluate the error in the primary variable. The problem addressed was that verification based solely on the 4–20 mA signal did not clearly identify the source of the measurement error. Therefore, HART communication was used to access the transmitter’s internal information and complement the evaluation. The study was conducted experimentally over a range of 0 to 100 °C, using a precision potentiometer as a resistive simulator of a Pt100 sensor. The equivalent resistance values were determined from the resistance–temperature relationship established in IEC 60751. Five points corresponding to 0%, 25%, 50%, 75%, and 100% of the range were evaluated. The reference temperature, Primary Variable (PV), and analog output were recorded using a HART 475 OEM communicator, and the PV error was calculated as the difference between the measured value and the reference value, in accordance with JCGM 200:2012. Before the Zero PV adjustment, the errors were +0.14 °C, +0.14 °C, +0.26 °C, +0.29 °C, and +0.21 °C. After the adjustment, they decreased to +0.02 °C, +0.01 °C, +0.02 °C, +0.01 °C, and +0.02 °C, respectively, and remained within the ±0.1% full-scale limit specified for the transmitter. As a contribution, a procedure for verification, diagnosis, adjustment, and post-adjustment verification using HART was established, which could be used as a guide for instrumentation laboratory practices. It was concluded that the HART protocol enabled a technical intervention based on the comparison between the PV and its reference value and allowed the reduction in measurement error after the adjustment to be quantitatively verified. | |
| dc.format.extent | 76 páginas | |
| dc.identifier.citation | Siza Tigse, K. A., & Tigasi Licto, J. I. (2026). Aplicación del protocolo hart en el proceso de calibración de transmisores de temperatura [Tesis de ingeniería, Universidad Técnica de Cotopaxi] | |
| dc.identifier.other | UTC-CIYA-ELM-2026-018-TS | |
| dc.identifier.uri | https://repositorio.utc.edu.ec/handle/123456789/15919 | |
| dc.language.iso | es | |
| dc.publisher | Universidad Técnica de Cotopaxi (UTC). Facultad de Ciencias de la Ingeniería y Aplicadas. Electromecánica | |
| dc.subject | Protocolo HART | |
| dc.subject | Transmisor de temperatura | |
| dc.subject | Pt100 | |
| dc.subject | Calibración | |
| dc.title | Aplicación del protocolo hart en el proceso de calibración de transmisores de temperatura | |
| dc.type | Thesis |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- UTC-CIYA-ELM-2026-018-TS.pdf
- Size:
- 2.74 MB
- Format:
- Adobe Portable Document Format
- Description:
- DOCUMENTO A TEXTO COMPLETO
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: