Al no contar con datos precisos de Eficiencia de los colectores solares de simple y doble flujo de movimiento de aire, se planteó en el presente proyecto, realizar un análisis comparativo del Rendimiento Térmico entre dichos colectores, mediante datos de temperatura obtenidos en pruebas experimentales, en similares condiciones ambientales y constructivas; dichos datos fueron tomados durante 11 horas consecutivas el 29 de junio del año 2023, desde las 07h00 hasta las 18h00. Para dicho objetivo, se empleó un módulo colector de datos, al cual se conectaron veinte termistores distribuidos en puntos estratégicos del colector para la toma de datos de Temperatura de Entrada, Interna y de Salida del colector, así como un anemómetro ubicado a la salida del colector, para la toma de datos de la velocidad del aire forzado; así mismo se empleó un soplador para la circulación del aire por el interior de cada colector. También se empleó una estación meteorológica, que permitió tomar datos en tiempo real de la Temperatura Ambiental y la Radiación Solar a la cual estuvieron expuestos los colectores. Una vez registrados los datos, se procedió a realizar un análisis comparativo del Rendimiento Térmico entre los dos colectores, concluyendo que el colector de doble flujo puede generar mayores Temperaturas de Salida, siendo 35,13°C la Máxima Temperatura registrada por el colector de doble flujo y de 33,56°C registrada por el colector de simple flujo. Así mismo se obtuvo un Rendimiento Térmico Promedio de 51% y 27% de los colectores de doble y simple flujo respectivamente, con una Radiación Solar promedio de 461,76 W/m2 y Temperatura Ambiental Promedio de 15,53 °C.
Description
As we do not have precise data on the efficiency of solar collectors with single and double flow of air movement, it was proposed in this project to carry out a comparative analysis of the Thermal Performance between said collectors, using temperature data obtained in experimental tests, in similar environmental and construction conditions; These data were taken for 11 consecutive hours on June 29, 2023, from 7:00 a.m. to 6:00 p.m. For this objective, a data collector module was used, to which twenty thermistors were connected distributed in strategic points of the collector to collect data on the Inlet, Internal and Outlet Temperature of the collector, as well as an anemometer located at the outlet of the collector. collector, for collecting forced air velocity data; Likewise, a blower was used to circulate air inside each collector. A meteorological station was also used, which allowed real-time data to be taken on the Environmental Temperature and Solar Radiation to which the collectors were exposed. Once the data was recorded, a comparative analysis of the Thermal Performance between the two collectors was carried out, concluding that the double flow collector can generate higher Outlet Temperatures, with 35.13°C being the Maximum Temperature recorded by the double flow collector. flow and 33.56°C recorded by the single flow collector. Likewise, an Average Thermal Performance of 51% and 27% was obtained from the double and single flow collectors respectively, with an average Solar Radiation of 461.76 W/m2 and Average Environmental Temperature of 15.53 °C.
Keywords
COLECTOR SOLAR, PLACA ABSORBENTE, SIMPLE FLUJO, ENERGÍA SOLAR
Citation
Ramos Ramos Marco Patricio (2023), Análisis comparativo del rendimiento térmico entre colectores solares de doble y simple flujo de movimiento del aire. UTC. Latacunga. 72 p