Análisis de la radiación solar para determinar un sistema fotovoltaico que permita abastecer la demanda eléctrica de un módulo didáctico eléctrico del Instituto Tecnológico Francisco de Orellana, ciudad de Puyo Provincia de Pastaza.
No Thumbnail Available
Date
2022
Authors
Advisors
Journal Title
Journal ISSN
Volume Title
Publisher
Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)
Abstract
El presente trabajo de investigación trata el análisis de la radiación solar, que determinará un sistema fotovoltaico que permita abastecer la demanda eléctrica de un módulo didáctico eléctrico del Instituto Tecnológico Francisco de Orellana; en la investigación se efectuó una serie de lectura de datos durante 12 meses, determinando de esta manera la radiación solar en el sitio de estudio, de esta manera, se determinó el peor mes correspondiente al mes marzo con una energía obtenida del sistema de 4416.2 [Wh/m² día], funcionando desde las 8:00 am hasta las 17:00 pm, en este tiempo se determina una irradiancia mínima 99.1 [W/m²] de 16:30 pm a 17:00 pm, así mismo el día típico arrojó una hora pico sol de 4.4; del estudio de cargas del grupo de módulos didácticos se determinó que: la energía que consume en el tiempo determinado de utilización y que por lo general es en las noches es 3672 Wh/día. Finalmente se realizó un análisis de costos de instalación que corresponde a 3073.85 dólares.
Description
The present research work deals with the analysis of solar radiation that will determine a photovoltaic system that allows to supply the electrical demand of an electrical didactic module of the Francisco de Orellana Technological Institute, in the investigation a series of data reading was carried out during 12 months, determining in this way the solar radiation in the study site, in this way the worst month corresponding to the month of March was determined with an energy obtained from the system of 4416.2 [Wh/m² day], operating from 8:00 a.m. to 5:00 p.m. :00 pm, at this time a minimum irradiance of 99.1 [W/m²] is determined from 16:30 pm to 17:00 pm, likewise the typical day showed a peak sun hour of 4.4; From the load study of the group of didactic modules, it was determined that: the energy consumed in the determined time of use and that is generally at night is 3672 Wh/day. Finally, an analysis of installation costs was carried out, which corresponds to 3073.85 dollars.KEY WORDS: Solar radiation; photovoltaic system; teaching module.
Keywords
RADIACIÓN SOLAR, SISTEMA FOTOVOLTAICO, MODULO DIDÁCTICO
Citation
Pérez Romero Diego Fernando (2022); Análisis de la radiación solar para determinar un sistema fotovoltaico que permita abastecer la demanda eléctrica de un módulo didáctico eléctrico del Instituto Tecnológico Francisco de Orellana, ciudad de Puyo Provincia de Pastaza. UTC. Latacunga. 110 p.