Estudio del sistema eléctrico para determinar la capacidad del sistema e implementar nuevas cargas en la empresa inplastico.
No Thumbnail Available
Date
2018
Advisors
Journal Title
Journal ISSN
Volume Title
Publisher
Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
Abstract
El presente trabajo de investigación realizado en la empresa INPLÁSTICO en la cuidad de Latacunga ubicada en el sector el Niagara, donde se efectuó el estudio del sistema eléctrico con el propósito de incrementar potencia, siendo necesario el levantamiento de carga y la actualización del diagrama unifilar. Con la ayuda del analizador de carga FLUKE 435 se realizó mediciones a los 2 transformadores de marca TRANSUNEL 200 kVA 13,8 kV/220 V y al de 200 kVA 13,8 kV/440 V con lo cual se obtuvo datos de voltaje, corriente, potencias, factor de potencia. La medición se ejecutó en un periodo de 5 días laborables de la empresa en intervalo de 10 minutos conforme a la regulación 004/01 emitido por ARCONEL, posteriormente con los datos recopilados por el analizador se realizó un análisis mediante histogramas de frecuencia obteniendo la curva diaria de voltaje corriente, potencia, factores de potencia. La interpretación de datos recogidos por el levantamiento de carga se elaboró la simulación en el programa ETAP 12.6.0 con la actual carga y la nueva carga, donde se identificaron problemas, transformador sobrecargado, caídas de voltaje, conductores sobrecargados, fugas de corrientes en los sistemas eléctricos y perdidos. Los resultados de la investigación permitieron dar soluciones técnicas al sistema eléctrico.
Description
The following research job took place at INPLASTICO industry in Latacunga city at Niagara. The study of electric systems was conducted with the purpose of increasing the electrical power, and as a result both charge rise and the updating of single-line diagram was required. With helping of FLUKE 435 charge analyser, measurements were carried out to 2 brand transformers which were TRANSUNEL 200 kVA 13,8 kV/220 V and 200 kVA 13,8 kV/440 V. Thanks to this, important data concerned to voltage, current, power and power factors were achieved. Measurement was conducted in a period of five working days at the industry between intervals of 10 minutes according to regulation 004/01 submitted by ARCONEL. Subsequently, the use of data collected by the analyser allowed a global analysis through frequency histograms to obtain a daily scale of voltage, current, power and power factors. The interpretation of data gathered from charge rise was executed. There was also a simulation by using the ETAP 12.6.0 program with ongoing charge and new charge. So, problems such as overload transformer, voltage falls, overload conductors, current leaks could be identified at the electric and lost systems. Results in the research allowed to reach technical solutions to the electric system.
Keywords
ELÉCTRICO, CAPACIDAD, CARGAS
Citation
Chuquitarco Gudiño Ana de las Mercedes Cajas Paucar Darwin Ricardo (2019); Estudio del sistema eléctrico para determinar la capacidad del sistema e implementar nuevas cargas en la empresa inplastico. UTC. Latacunga. 127 p.