Evaluación del sistema hidrosanitario de los bloques A y B de la Universidad Técnica de Cotopaxi, Campus Matriz.
dc.contributor.advisor | Mogro Cepeda, Yenson Vinicio | |
dc.contributor.author | Alpusig Chuqui, Hugo Geovanny | |
dc.contributor.author | Bustos Arias, Jeniffer Nicole | |
dc.date.accessioned | 2024-10-07T16:26:29Z | |
dc.date.available | 2024-10-07T16:26:29Z | |
dc.date.issued | 2024-08 | |
dc.description | Los sistemas hidrosanitarios son parte fundamental del desarrollo y crecimiento de una sociedad, ya que a través de esto podemos prevenir problemas futuros. El presente trabajo tiene como objetivo evaluar del sistema hidrosanitario para los Bloques A y B de la Universidad Técnica de Cotopaxi, Campus Matriz, mediante información de campo para identificar la condición y situación actual en que se encuentra. El método de investigación es cuantitativo porque nos permite medir y analizar datos de manera eficiente, comparar resultados con estándares y normativas vigentes en nuestro país. Las dotaciones para el consumo de agua se determinaron de acuerdo con las recomendaciones de la NEC11 (Norma Ecuatoriana de la Construcción), Capítulo 16, en relación con la dotación asignada para edificios de estas características. Los parámetros para el diseño de aguas servidas y aguas lluvias se seleccionaron de las Normas para Estudio y Diseño de Agua Potable y Aguas Residuales del INEN (Instituto Ecuatoriano de Normalización).Los resultados más destacados de la investigación demostraron que la presión en los diferentes pisos se encuentra entre 15 y 35 PSI, cumpliendo con los requisitos establecidos por las normativas vigentes y asegurando el correcto funcionamiento de los aparatos sanitarios, que requieren un mínimo de 14.22 PSI, sin embargo, debido a una alta demanda de servicio, el sistema de bombeo requiere una potencia más alta de la que se tiene. Además, se identificaron áreas que no estaban contempladas en los planos iniciales, lo que resaltó la importancia de realizar una inspección detallada en el sitio para posteriormente actualizar las modificaciones de diseño, Finalmente se recomienda a los futuros ingenieros utilizar métodos y normativas actualizadas que rijan en el país, para los respectivos cálculos y diseños hidrosanitarios. | |
dc.description.abstract | Hydro sanitary systems are a fundamental part of the society development and growth, as they help prevent future problems. Evaluating the hydrosanitary system to A and B blocks from the Technical University of Cotopaxi, Matrix Campus was the objective, through field information to identify the current condition and situation. The research method is quantitative because allows us to measure and analyze data efficiently and compare results with current standards and regulations in the country. Water supply provisions were determined according to the recommendations of NEC11 (Ecuadorian Construction Standard), Chapter 16, concerning the supply assigned for buildings of these characteristics. The parameters design for wastewater and rainwater were selected from the Standards for the Study and Design of Drinking Water and Wastewater of INEN (Ecuadorian Institute of Standardization). The most significant results about this research demonstrated that the pressure on the different floors ranges between 15 and 35 PSI, complying with the requirements established by current regulations and ensuring the proper functioning of sanitary appliances, which require a minimum of 14.22 PSI. However, due to a high service demand, the pumping system requires higher power than currently available. Additionally, areas that were not included in the original plans were identified, highlighting the conducting importance a detailed on-site inspection to subsequently update the design modifications. Finally, it is recommended that future engineers use updated methods and regulations in the country for the respective hydrosanitary calculations and designs. | |
dc.format.extent | 96 páginas | |
dc.identifier.citation | Alpusig Chuqui Hugo Geovanny y Bustos Arias Jeniffer Nicole (2024); Evaluación del sistema hidrosanitario de los bloques A y B de la Universidad Técnica de Cotopaxi, Campus Matriz. UTC. Latacunga. 96 p. | |
dc.identifier.other | PI-002907 | |
dc.identifier.uri | https://repositorio.utc.edu.ec/handle/123456789/12321 | |
dc.language.iso | es | |
dc.publisher | Ecuador: Latacunga: Universidad Técnica de Cotopaxi: (UTC) | |
dc.subject | RED DE AGUA POTABLE | |
dc.subject | RED DE AGUA SANITARIA | |
dc.subject | RED DE AGUA PLUVIAL UNIVERSIDAD TÉCNICA DE COTOPAXI | |
dc.subject | DOTACIONES | |
dc.title | Evaluación del sistema hidrosanitario de los bloques A y B de la Universidad Técnica de Cotopaxi, Campus Matriz. | |
dc.type | Thesis |